Siemens TeleControl Server Basic
cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*
- < V3.1.2.2
A SQL injection vulnerability has been identified in Siemens TeleControl Server Basic, affecting all versions prior to 3.1.2.2. The vulnerability arises in the 'LockDatabaseSettings' method, allowing authenticated remote attackers to bypass authorization controls, manipulate the application's database, and execute code with 'NT AUTHORITY\NetworkService' permissions. Exploitation requires access to port 8000 on the vulnerable system.
Exploitation of this vulnerability could lead to unauthorized database access and manipulation, as well as code execution in the operating system's shell with limited 'NT AUTHORITY\NetworkService' permissions.
Users are advised to update TeleControl Server Basic to version 3.1.2.2 or later. For more information, visit the Siemens support page.
Our algorithm analyzes dozens of metrics to generate these 8 key vulnerability categories, which are then combined to calculate the overall risk score.